11211 - 154 St. Edmonton, Alberta, Canada T5M 1X8 sales@alfaradio.ca 780 466 5779 www.alfaradio.ca
AZIMUTH – motor rotates in azimuth,
ELEVATION – motor rotates in elevation.
INPUT
Sensor type of controller MD-01 (only when the input type is
DIGITAL):
ELECTRONIC – rotator using electronic motion sensors (HALL
Effect),
MECHANIC - rotator using mechanical switches.
GEAR
Gear ratio of the rotator motor. Example 0.0937 for RAS/HR, 1.0000
for RAU and 0.5000 for BIG-RAK
MIN ANGLE
Minimum angle, it is possible to limit turning for the motor.
Default -180
MAX ANGLE
Maximum angle, it is possible to limit turning for the motor.
Default +180
MAX POWER
Maximum power as a percentage of full power, which the controller
can provide to the rotator motor.
START POWER, START TIME
Used if you want to obtain a so-called “soft-start”. You can set a
one, two or three-stage motor start
(START POWER 1, POWER START 2, and START POWER 3)
Power is expressed as a percentage of full power.
(START TIME 1, START TIME 2 and START TIME 3)
START TIME is expressed in seconds.