Page 18 of 20 file ~alfaspid/md-01/AlfaSpid_MD-01_Operation_15April2013_Master.doc April 15, 2013
11211 - 154 St. Edmonton, Alberta, Canada T5M 1X8 sales@alfaradio.ca 780 466 5779 www.alfaradio.ca
STOP POWER, STOP TIME
Used, if you want to obtain a so-called “soft stop”. It works the
same way as “soft start” except in the other way.
STOP AT
Specifies how many degrees before the specified angle (for example,
sent by a computer program like Orbitron) is to start the motor
stopping. It only applies when Soft STOP is selected in MOTOR
CONFIGURATION.
PULSE TIMEOUT
Specifies how long the motor will run if it does not receive motion
pulses from the rotator. Applies only to motors of type DIGITAL.
SET COM 0, SET COM 1
STATE
Read only. Possible values: ON or OFF.
BAUD
Possible values: 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200, 230400 and 460800.
DATA BITS
Possible values: 4,5,6,7 or 8 bit.
STOP BITS
Possible values: 1 or 2 bit.
PARITY
Possible values: none, odd or even.